Sales, Repair, Maintenance & Certification
of all makes of the following

(Micro)Biological Safety Cabinets
(Class I, II and III)

(Micro)Biological Safety Cabinets also known as Biosafety Cabinets are for personnel, product/sample and environmental protection. Tested in accordance with applicable National and(or) International Standards for all types and makes of Biosafety Cabinets by internationally and nationally certified technicians. Services include but not limited to Decontamination, DOP Testing, Air Flow Velocity Testing; Smoke Visualisation Verification; Setpoint Calibrations, Comprehensive reporting.

Sales, Repairs and Training offered.

Laminar Flow Cabinets Vertical

Laminar Flow Benches are used for product/sample protection and are tested in accordance to applicable National and(or) International Standards for all types and makes of Laminar Flow Cabinets by internationally and nationally certified technicians. Services include but not limited to HEPA Filter Testing; Primary Filter Replacement; Air Flow Velocity Testing; Smoke Visualisation Verification; Setpoint Calibrations, Comprehensive reporting.

Sales, Repairs and Training offered.

Fume Cabinets / Hoods

Fume Cabinets or Hoods are used to vent fumes and gasses either by extraction to exterior or recirculated through carbon absorbing filters to protect personnel. Tested in accordance to applicable National and(or) International Standards for all types and makes of Fume Hoods and Cabinets by internationally and nationally certified technicians. Services include but not limited to Air Flow Velocity Testing; Smoke Visualisation Verification; Setpoint Calibrations, Carbon Filter Replacements (where applicable) Comprehensive reporting.

Sales, Repairs and Training offered.

BSL 1-4 Laboratories

BSL 1-4 Laboratories are controlled negative pressurized air containment environments and spaces for protection of personnel, product/sample and environmental spaces.

Tested in accordance with applicable National and(or) International Standards for all BSL 1-4 Laboratories by internationally and nationally certified technicians. Services include but not limited to Decontamination, HVAC Validation; Bag-In-Bag-Out Housing Testing; Pressure Decay Testing; HEPA Filter / Terminal HEPA Filter DOP Testing; Pressure Cascades Verification & Calibration; Air Change Rates (ACR) verification & Calibration; BMS Setpoint adjustments;  Air Flow Velocity Testing; Smoke Visualisation Verification; Setpoint Calibrations, Comprehensive reporting. Other services include Fogging; Fault Finding; Filter Replacements; HVAC Renovations; Training etc.

Cleanrooms & Aseptic Rooms

Cleanroom and Aseptic Rooms are controlled positive pressurized air containment environments and spaces for protection of personnel, product/sample and environmental spaces.

Tested in accordance with applicable National and(or) International Standards for all Cleanrooms and Aseptic Rooms by internationally and nationally certified technicians. Services include but not limited to HVAC Validation; HEPA Filter / Terminal HEPA Filter DOP Testing; Particle Counting and Iso Classification; Pressure Cascades Verification & Calibration; Active Sample Plate Testing; Air Change Rates (ACR) verification & Calibration; BMS Setpoint adjustments; Air Flow Velocity Testing; Smoke Visualisation Verification; Setpoint Calibrations, Comprehensive reporting. Other services include Fogging; Fault Finding; Filter Replacements; HVAC Renovations; Training etc.

Hospital Theatres

Hospital Operating Theatres are controlled air containment environments conforming to ISO Classifications.

Tested in accordance with applicable National and(or) International Standards for all Hospital Operating Theatres by internationally and nationally certified technicians. Services include but not limited to HVAC Validation; HEPA Filter / Terminal HEPA Filter DOP Testing; Particle Counting and Iso Classification; Pressure Cascades Verification & Calibration; Air Change Rates (ACR) verification & Calibration; Air Flow Velocity Testing; Smoke Visualisation Verification; Comprehensive reporting. Other services include Fault Finding; Filter Replacements; HVAC Renovations; etc.

HVAC Systems

HVAC systems are for supplying and exhausting filtered air from and to controlled environments.

Tested in accordance with applicable National and(or) International Standards for all HVAC Filtration Units by internationally and nationally certified technicians. Services include but not limited to Full maintenance; Fault Finding; Filter Replacements; Decontamination, HVAC Validation; Bag-In-Bag-Out Housing Testing; Pressure Decay Testing; HEPA Filter DOP Testing; BMS Setpoint adjustments and calibrations; Air Flow Velocity Testing; Smoke Visualisation Verification; Renovations and Adjustments; Comprehensive reporting. Other services offered includes maintenance and repairs of airconditioning units.

HEPA Filters and Filtration

We supply and test all makes of ULPA, HEPA, HEGA, Carbon, Secondary and Primary Filters for HVAC & PPU, Laminar Flow Terminal HEPA Filter Units, Cleanrooms; Hospital theatres; BSL1-4 Laboratories, Biosafety Cabinets, Laminar Flow Benches, Fume Hoods.

Expert Technical Consultations

CAT-TECH is centered on offering the best quality service
focussing on safety and productivity